Vignette-270-200_Publi

Towards a safer transport of liquid hydrogen: exploring the combustion of hydrogen/air mixtures at sub-zero temperature through laminar flame speeds measurements

Faits marquants

Towards a safer transport of liquid hydrogen: exploring the combustion of hydrogen/air mixtures at sub-zero temperature through laminar flame speeds measurements

Pascal Diévart1,2, Yves Ballossier3, Nabiha Chaumeix1

1ICARE, CNRS Ingénierie, Orléans, France
2Université d’Orléans, France
3Institut Pprime, CNRS Ingénierie, ISAE-ENSMA, Université de Poitiers, France

The appeal of hydrogen as a clean energy vector must come with the development of a distribution infrastructure. Some stages of this infrastructure will be operated at cryogenic conditions, that might result with liquid hydrogen leakage and/or spillage that will be in contact with air. Such risks and their consequences must therefore be assessed in order to delineate appropriate safety measures. A deep knowledge of the hydrogen/air flame fundamental properties at such cryogenic conditions is thus necessary. However, only a limited number of data is currently available for both laminar flame speeds and flammability limits. In order to bridge this gap, we have developed an experimental facility that allows investigating the combustion of H2/air mixtures at cryogenic temperatures. It consists in a cylindrical vessel (4.65 L volume) with multiple ports on the radial walls to host gas inlet and outlet as well as thermocouples and an ignition system. Along the cylindrical axis, two polycarbonate windows (140 mm diameter) provide optical access to visualize the flame through a Schlieren diagnostic. The vessel is cooled down by a thermal fluid, the temperature of which is controlled by an external circulating cryostat. To prevent heat exchange between the cold cylindrical bomb and the outside, the bomb is located in a double wall stainless-steel chamber that is constantly under vacuum.

The laminar flame velocities S_L^0 of hydrogen/air mixtures have been measured with this setup at temperatures as low as -60°C, over a large range of equivalence ratios. At room temperature, our measurements are in excellent agreement with the data reported in the literature. It is observed that the flame velocity decreases with the temperature, whereas the maximum pressure after combustion increases.

The authors acknowledge support from the French National Research Agency (ANR) under France 2030 program and reference ANR-22-PEHY-0017 (project PEPRH2: ESKHYMO)